A Tough Instrument for Tough Environments
Level measurement of bulk solids
Bulk solids, which vary widely in their density, form and features, confront the measuring instruments in industrial production processes with widely different challenges: powders often generate huge clouds of dust, while coarse, heavy bulk solids cause tremors and noise when being filled into a container from a great height. With VEGAPULS 68, level measurement in bulk solids is largely independent of process conditions. Due to optimized VEGA radar technology, the sensor can evaluate signals 1,000 times smaller than those conventional radar instruments can pick up. This high sensitivity allows a measuring range of up to 75 m even in products with bad reflective properties.
Operating Principle:
RadarFeatures:
- Non-contact measurement
- High plant availability, because wear and maintenance-free
- Reliable measurement independent of vapour, dust and noise
Application:
VEGAPULS 68 is the level measuring transducer for extreme bulk solids applications in silos of all kinds. Continuous monitoring of bulk solids with VEGAPULS 68 is largely independent of process conditions such as high temperatures or dusty environment, e.g. in coal handling systems in power plants or in storage facilities for building materials such as clinker or cement. Level measuring transducer VEGAPULS 68 – for level monitoring of bulk solids in all industries:
- Solids and powders
- Fuel
- Storage of wood pellets
- Pumped storage power plant
- Storage of solid materials
- Fuels
- Cement silo
- Clinker silo
- Clinker cooler
- Aggregates and raw meal
- Blending bed
- Granulate silos in plastic recycling
- Incinerator
- Liquefied gas
- Aluminium smelting
- Blast furnace
- Steel production
- Mining of ore
- Food ingredients
- Ready asphalt
- Fine lime silo
- Lime kiln
- Buffer and production silos
- Large silos for stocking
- Storage of bulk solids
- Digestion tower
- Lime and fly ash silo
- Coal bunker in a power station
- Bleaching process
- Wood chip silo
Specification:
- Measuring range: up to 75 m
- Process fitting: thread from G1½, 1½ NPT flanges from DN 50, 2″
- Process temperature: -200 … +450 °C
- Process pressure: -1 … +160 bar (-100 … +16000 kPa)
- Measurement accuracy: +/- 2 mm
- SIL qualification: optionally up to SIL2