The hygienic level switch KMW is microprocessor based and can be installed in any position in tanks or piping systems. The measuring principle is an electromagnetic wave. A high frequency signal sweep is radiated from the sensor tip into the tank or pipe. The medium acts as a virtual capacitor. This virtual capacity will depend of the dielectric value of the medium and is well defined for most media. Therefore the KMW is suitable for almost all liquids and paste-like medias. There are 7 base settings for several medias.
Operating Principle:
ElectromagneticFeatures:
- All stainless steel design
- EHEGD certified
- Small and compact
- CIP / SIP Cleanable
- No moving parts
- Adjustable sensitivity
- Fast response time
- 7 basic adjustments
- Calibration via dip-switch or pc
Application:
The KMW is suitable for almost all liquids and paste-like medias.
Specification:
- Electromagnetic wave : 100… 180 MHz
- Power supply : 18… 32 Vdc
- Output : PNP Adjustment : via dip-switch or PC
- Wetted parts : AISI 316L and PEEK
- Material housing : AISI 304
- Electrical connection : M12 plug or PG gland Accuracy : ± 1 mm
- Response time : < 0,2s Damping : 0 … 8 s
- Ambiant temperature : –10…+70°C
- Process temperature : 0…+ 150°C
- Protection class : IP67
Process pressure : Max. 25 bar Internal indication : L