The FLX level switch is based on the principle of conductivity. It is an all stainless steel level switch with a rugged design. The FLX can be used in all kinds of conductive liquids. Various sanitary process connections are available, for use in the Food & Beverage industry, like: G1” (1”BSP) with sanitary weld-on nipple, milk-coupling, tri-clamp or flanges. There are several executions available, like extended probes without electronics which can be shortened by the customer at any length, or our “flush” mounted version without insertion length.
Operating Principle:
ConductivityFeatures:
- All stainless design
- Sanitary process connections
- Adjustable sensitivity
- Easy installation
- Relay or PNP output
- Maintenance free
- Exchangeable electronics
Application:
For use in the Food & Beverage industry
Specification:
- Principle : Conductivity
- Process connections : G1” (1” BSP) (standard); Various process connections (see ordering code)
- Material housing : SS 304
- Material sensor : SS 316 L + PEEK (Insulation part 8) (Option: Ceramic for HT)
- Insertion length : 100 mm (standard) From 20 mm to 2 meter (specify)
- Process temperature : -30°C to +100°C (140°C/45 mins) (Option to +180°C)
- Ambient temperature : -20°C to +60°C
- Maximum pressure : 10 bar
- Protection grade : IP67
- Electrical connection : PG9, 1/2” NPT or M20
- Power supply : 20 – 28 Vdc Output : Relay or PNP